Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors ws

59,00 zł
DARMOWA wysyłka

Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors ws

  • Marka: Unbranded
Sprzedawca:

Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors ws

  • Marka: Unbranded

59,00 zł

W magazynie
DARMOWA wysyłka
Sprzedawca:

59,00 zł

W magazynie
DARMOWA wysyłka

Akceptujemy następujące metody płatności

Opis

Relay Module 32 Functions Safe Reliable Digital Delay Timer Control Switch for DC Motors ws

Item Type:Relay Module Product Model: YF-11 Input Voltage:DC7-24V Output Power: Can Control DC Power Load within 10A Time Range: 0.01 Second to 999 Minutes, Any Time Adjustable Function: Pulse Trigger Cycle, Timing, Delay, Power Tube, mos Tube, Field Effect Tube, Switch, Relay Switch Application: It is Often Used to Control Motors, LED Light Strips, DC Motors, Micro Water Pumps, Solenoid Valves, Etc. P-21: Give the signal, after a delay of A second, the output starts P-22: Give the signal, after more than A second, the output starts, the signal disappears, and the output stops P-23: After the signal disappears for more than A seconds, the output starts, there is a signal, and the output stops P-24: There is a signal. After A second, the output starts, and after the signal disappears for more than A second, the output stops. P-25: When there is a signal, the output will start after A second, and the output will stop when there is another signal for more than A second P-26: There is a signal, the output stops after A second, and the signal disappears and the output stops after A second. P-27: Detection of a pulse signal, the output stops no pulse signal, more than A second output start (the signal continues or the signal disappears are regarded as no pulse signal) P-28: After power on, after a delay of A second, the output starts until the power is off P-31: After power on, the output starts for A second, stops for B second, infinite loop power off stops P-32: When there is a signal, start P-31 infinite loop when the signal disappears, terminate the loop P-33: Give a signal to start P-31 infinite loop give another signal to terminate the loop P-34: After power-on, after a delay of A second, the output will start, and it will stop after closing B seconds P-35: There is a signal, after a delay of A second, the output will start, and it will stop after the pull-in for B seconds P-36: There is a signal, the output will start after A second, and stop after B second, the signal disappears, and the timer will be cleared and stopped. P-37: When there is a signal, the output starts and stops automatically for A second, and then counts for B seconds after it stops. The signal trigger is invalid within AandB time P-38: There is a signal, the output starts and stops automatically for A second, after stopping and counting for B seconds, restarting for A second automatically stops P-41: No action with signal trigger when signal disappears disconnect after output start delay A time P-42: The signal disappears, after a delay of time A, the output starts working time B ends P-43: The signal disappears. After the time A exceeds, the output starts the working time B ends P-44: After power on, the output will start A time, stop B time cycle C times and automatically stop. P-45: No action when energized, after signal is given output starts A time, stops B time cycle C times and automatically stops Give signal again, execute again P-46: After giving the signal more than A times, the output will start keep the output stop when the power is off P-47: After giving the signal more than A times, the output starts and stops for B seconds P-48: Within C seconds, after continuously giving the signal more than A times, the output starts and stops in B seconds 3. Description of button setting: Power on display "" means entering standby state Press K1 for the first time, (it takes more than 1 second to be effective to prevent false triggering) Display: P -11: K2 adjustment main mode, K3K4 adjustment function Press K1 for the second time, the screen displays: A001: K2 and K3 adjust the first time A, K4 adjusts the decimal point (time unit) Press K1 for the third time, the screen displays: B001: K2 and K3 adjust the second time B, K4 adjusts the decimal point (time unit) Press K1 for the fourth time, the display "" means entering the standby state Press K4 in standby mode to permanently turn off or on the display and switch to low power consumption mode 4. The decimal point time unit description: X.XX The decimal point is in hundreds, and the timing range: 0.01 seconds to 9.99 seconds XX.X The decimal point is in the tenth place, timing range: 0.1 second to 99.9 seconds XXX has no decimal point, timing range: 1 second to 999 seconds XXX. The decimal point is in the ones place, and the timing range: 1 minute to 999 minutes Note: Due to the light and screen setting difference, the item's color may be slightly different from the pictures. Please allow slight dimension difference due to different manual measurement.
  • Identyfikator Fruugo: 434569827-911853955
  • EAN: 9316197747620

Dostawa i zwroty

Wysyłka w ciągu 2 dni

  • STANDARD: BEZ OPŁAT - Dostawa między pon. 15 grudnia 2025–pon. 22 grudnia 2025 - BEZ OPŁAT

Wysyłka z Chiny

Dokładamy wszelkich starań, aby zamówione produkty były dostarczane w całości i zgodnie z Państwa wymaganiami. Jeśli jednak otrzymają Państwo niekompletne zamówienie, przedmioty inne niż zamówione lub istnieje inny powód, dla którego nie są Państwo zadowoleni z zamówienia, mogą Państwo zwrócić zamówienie lub dowolne produkty objęte zamówieniem i otrzymać pełny zwrot kosztów za te przedmioty. Pokaż pełną politykę zwrotów

Szczegóły zgodności produktu

Prosimy o zapoznanie się z informacjami dotyczącymi zgodności dotyczącymi tego produktu podanymi poniżej.

Poniższe informacje zostały dostarczone przez niezależnego sprzedawcę zewnętrznego sprzedającego ten produkt.

Producent:
Poniższe informacje zawierają dane kontaktowe producenta danego produktu sprzedawanego w serwisie Fruugo.

  • Foshan Panweibai Trading Co., Ltd.
  • Foshan Panweibai Trading Co., Ltd.
  • Room 103, No. 57, Shalong Road, Jiujiang Town, Nanhai District, Foshan City
  • Foshan
  • CN
  • 528203
  • razer0815@outlook.com
  • 13790744267

Osoba odpowiedzialna w UE:
Poniższe informacje zawierają dane kontaktowe osoby odpowiedzialnej w UE. Osobą odpowiedzialną jest wyznaczony przedsiębiorca z siedzibą w UE, który jest odpowiedzialny za wypełnianie obowiązków związanych z przestrzeganiem przepisów w odniesieniu do danego produktu sprzedawanego na terenie Unii Europejskiej.

  • Jean Luc
  • In Memoria Futuri SAS
  • 3 RUE DU PAS DE LA MULE 75004 PARIS
  • Paris
  • France
  • 75004
  • infoapexchen@gmail.com
  • 33745713901