Description
W1209 DC 12V Heat Cool Digital Thermostat Temperature Controller Miniature Thermostat Temperature Control Switch Panel
Specifications:
Temperature range :-50 to 110
Dimensions: 48.5 x 40mm
Temperature control mode: ON / OFF
Resolution:When temperature is 0.1, the resolution is -9.9~99.9, other temperature segment is 1
Control accuracy: 0.1
Hysteresis accuracy: 0.1
Refresh rate: 0.5S
High temperature protection: 0-110
Supply voltage: DC 12V
Static current: 35mA, attract current 65mA
Output voltage: DC 12V
Output power: 20A relay
Measurement input: (10K 0.5%) Waterproof Sensor
Environmental requirements: -10 ~ 60 C ,Humidity 20% -85%
Settings Chart
Long press the SET button to activate the menu.
Description Range Default Value
P0 Heat C/H C
P1 Backlash Set 0.1-15 2
P2 Upper Limit 110 110
P3 Lower Limit -50 -50
P4 Correction -7.0 ~ 7.0 0
P5 Delay Start Time 0-10 mins 0
P6 High Temperature Alarm 0-110 OFF
Long pressing +- will reset all values to their default
Displaying the current temperature:
The_x000D_
thermostat will display the current temperature in C by default. When _x000D_
in any other mode making no input for approximately 5 seconds will cause_x000D_
the thermostat to return to this default display.
Setting the trigger temperature:
To_x000D_
set the trigger temperature press the button marked 'SET'. The seven _x000D_
segment display will flash. You can now set a trigger temperature (in _x000D_
C) using the '+' and '-' buttons in 0.1 degree increments. If no _x000D_
buttons are pressed for approximately 2 seconds the trigger temperature _x000D_
will be stored and the display will return back to the current _x000D_
temperature.
Setting the parameters:
To set any parameter long press the 'SET' button for at least 5 seconds. The seven _x000D_
segment display should now display 'P0'. This represents parameter P0. _x000D_
Pressing the '+' or '-' buttons will cycle though the various parameters_x000D_
(P0 to P6). Pressing the 'SET' button whilst any of there parameters _x000D_
are displayed will allow you to change the value for that parameter _x000D_
using the '+' and '-' buttons (see below). When finished setting a _x000D_
parameter press the set button to exit that option. If no buttons are _x000D_
pressed for approximately 5 seconds the thermostat will exit the _x000D_
parameter options and will return back to the default temperature _x000D_
display.
Setting the cooling or heating parameter P0:
The _x000D_
parameter P0 has two settings, C and H. When set to C (default) the _x000D_
relay will energise when the temperature is reached. Use this setting if_x000D_
connecting to an air-conditioning . When set to H the relay will _x000D_
de-energise when the temperature is reached. Use this setting if _x000D_
controlling a heating device.
Setting the hysteresis parameter P1:
This_x000D_
sets how much change in temperature must occur before the relay will _x000D_
change state. For example if set to the default 2C and the the trigger _x000D_
temperature has been set to 25C, it will not deenergise until the _x000D_
temperature falls back below below 23C. Setting this hysteresis helps _x000D_
stop the thermostat from continually triggering when the temperature _x000D_
drifts around the trip temperature.
Setting the upper limit of the thermostat parameter P2:
This_x000D_
parameter limits the maximum trigger temperature that can be set. It _x000D_
can be used as a safety to stop an excessively high trigger temperature _x000D_
from accidentally being set by the user.
Setting the lower limit of the thermostat parameter P3:
This_x000D_
parameter limits the minimum trigger temperature that can be set. It _x000D_
can be used as a safety to stop an excessively low trigger temperature _x000D_
from accidentally being set by the user.
Setting temperature offset correction parameter P4:
Should_x000D_
you find there is a difference between the displayed temperature and _x000D_
the actual temperature (for instance if the temperature probe is on a _x000D_
long run of cable) you can make corrections to the temperature _x000D_
reading with this parameter.
Setting the trigger delay parameter P5:
This_x000D_
parameter allows for delaying switching of the relay when the trigger _x000D_
temperature has be reached. The parameter can be set in minute _x000D_
increments up to a maximum of 10 minutes.
Setting the high _x000D_
temperature alarm parameter P6: Setting a value for this parameter will _x000D_
cause the relay to switch off when the the temperature reaches this _x000D_
setting. The seven segment display will also show '---' to indicate an _x000D_
alarm condition. The relay will not re-energise until the temperature _x000D_
falls below this value. Th
-
Fruugo ID:
357525244-777031846
-
EAN:
7574177971607
Product Safety Information
Please see the product safety information specific to this product outlined below
The following information is provided by the independent third-party retailer selling this product.
Product Safety Labels
Safety Warnings:
WARNING! TO AVOID DANGER OF SUFFOCATION,KEEP AWAY FROM BABIES ANDCHILDREN. DO NOT USE IN CRIBS/BEDSOR PLAY PENS.THIS BAG IS NOT ATOY.
Ingredients:
Octinoxate 7.448%
Manufacturer Part Number:
ZL778182
Model Number:
ZL764201
Serial Number:
ZL179058
Batch Number:
ZL357068
Delivery & Returns
Dispatched within 3 days
Shipping from China.
We do our best to ensure that the products that you order are delivered to you in full and according to your specifications. However, should you receive an incomplete order, or items different from the ones you ordered, or there is some other reason why you are not satisfied with the order, you may return the order, or any products included in the order, and receive a full refund for the items. View full return policy
Product Compliance Details
Please see the compliance information specific to this product outlined below.
The following information is provided by the independent third-party retailer selling this product.
Manufacturer
The following information outlines the contact details for the manufacturer of the relevant product sold on Fruugo.
- Bosidun Shenzhen Keji Youxian Gongsi
- Bosidun Shenzhen Keji Youxian Gongsi
- Longgangqu Pinghu Jiedao Hehua Shequ Huanan Dadao Yi Hao
- Huanan Guoji Fangzhi Fuzhuang Yuanfuliao Wuliuqu Erqi
- Shenzhen
- China
- 518000
- laureenoun@163.com
- 15678247948
- https://www.fruugoschweiz.com/bosidun-shenzhen-keji-youxian-gongsi/m-18796
Responsible Person in the EU
The following information outlines the contact information for the responsible person in the EU. The responsible person is the designated economic operator based in the EU who is responsible for the compliance obligations relating to the relevant product sold into the European Union.
- EC REP SERVICES SL
- EC REP SERVICES SL
- Calle Gran Via 49, 7 DCH.
- Madrid
- Spain
- 28013
- ECREPSERVICE@HOTMAIL.COM
- 34682797075