GM328A Transistor Diode LCD Tester LCR Capacitance ESR Voltage Frequency Meter PWM Square Wave Signal Generator Electronic Kits

139,00 zł
+ 48,49 zł wysyłka

GM328A Transistor Diode LCD Tester LCR Capacitance ESR Voltage Frequency Meter PWM Square Wave Signal Generator Electronic Kits

  • Marka: Unbranded

GM328A Transistor Diode LCD Tester LCR Capacitance ESR Voltage Frequency Meter PWM Square Wave Signal Generator Electronic Kits

  • Marka: Unbranded
Sugerowana cena detaliczna: 599,00 zł
Cena: 139,00 zł
Oszczędzasz: 460,00 zł (76%)
Sprzedawca:
139,00 zł
+ 48,49 zł wysyłka

W magazynie

Akceptujemy następujące metody płatności

Opis

GM328A Transistor Diode LCD Tester LCR Capacitance ESR Voltage Frequency Meter PWM Square Wave Signal Generator Electronic Kits Note: Some features are not available in the Russian version, please choose to purchase according to your needs~! Product parameters Input voltage: Type -C DC5V Self welding: DC 9V connector (DC 9V: requires self welding of connectors before use) Operating voltage: 30mA approx. Transistor tester control 1.The tester is controlled by a rotary encoder switch. 2.The rotary encoder switch can be operated in a total of 6 ways, short press, long press, left turn, right turn, press and hold left turn, press and hold right turn. 3.A short press in the off position turns the power on and starts the test. 4.After a test has been completed, if no device is detected. Press and hold the switch or rotate the switch left or right to enter the function menu. Once in the function menu, the left or right switch can be rotated up or down through the menu items, to enter a particular function item, press the switch once short. When it is necessary to exit from a certain function, then press the switch long. Test Devices The tester has 3 test points, TP1, TP2 and TP3, which are distributed in the test stand as follows On the right hand side of the test stand are the test positions for the SMD components, with the numbers 1,2,3, each representing TP1, TP2 and TP3 respectively. When testing components with only 2 pins, the pins are not divided into test order, 2 pins are chosen for any 2 test points, and the pins of 3-pin devices are placed in three test points, in no particular order. After the test, the tester automatically recognises the pin name of the component, the test point where it is located and displays it on the screen. When testing components with only 2 pins, if two test points are used, TP1 and TP3, the tester automatically enters continuous test mode after the test is completed, so that the components on TP1 and TP3 can be measured continuously and simultaneously without having to press the switch again. If "TP1 and TP2" or "TP2 and TP3" are used, only one test is performed. To test again, press the switch once. Note: Before testing the capacitor, discharge the capacitor before inserting it into the test holder for measurement, otherwise there is a risk of damaging the tester's microcontroller. 1,Calibration The tester calibration is used to eliminate errors in its own components, making the final test results more accurate. Calibration is divided into quick calibration and full function calibration. The operation method for quick calibration: short the three test points TP1, TP2 and TP3 with wires and then press the test button while watching the screen. The screen colour will change to white text on a black background. After the prompt message "Selftest mode...? ", press the test button to enter the fast calibration process; if, after the message "Selftest mode...? If no button is pressed within 2 seconds after the message "Selftest mode...", the normal test process is carried out and the resistance values of the three test points TP1, TP2 and TP3 are displayed at the end. After entering the quick calibration process, some data will appear on the screen, ignore it. Wait until a flashing string appears on the screen After "isolate Probes!", remove the shorted TP1, TP2 and TP3 leads. The quick calibration is complete until the string "Test End" appears on the screen. When calibrating for the first time, use the full function calibration method. The full function calibration is accessed from the function menu and requires an additional 220nf capacitor. Full function calibration performs a more comprehensive calibration process and can take longer. Once in the function menu, turn the test button to the menu item "Selftest", then press the test button to enter the full function calibration process, which starts with the flashing string "short Probes! When the flashing string "isolate Probes!" appears on the screen, remove the wires from the three test points and continue to wait for the calibration process to proceed, when the string "1-||- 3 > 100nf", install the prepared 220nf capacitors on test points TP1 and TP3. Wait until the screen says "Test End" and the fully functional calibration process is complete. 2. Function menu 2.1 Switch off 2.2 Transistor 2.3 Frequency Measures the frequency. Press and hold the test button to exit the frequency measurement function. The frequency measurement range is from 1 Hz to more than 1 MHz, when the measured frequency is below 25 KHz, the period is displayed 2.4 f-Generator Square wave generator with multiple square wave frequencies selectable, turn the test button left or right to switch between different square wave frequencies, long press the test button to exit the square wave generator. 2.5 10-bit PWM Pulse generator, left or right turn the test
  • Identyfikator Fruugo: 405876432-860618363
  • EAN: 7617000533532

Informacje o bezpieczeństwie produktu

Prosimy o zapoznanie się z informacjami dotyczącymi bezpieczeństwa produktu określonymi poniżej

Poniższe informacje zostały dostarczone przez niezależnego sprzedawcę zewnętrznego sprzedającego ten produkt.

Etykiety bezpieczeństwa produktu

CE Mark
Ostrzeżenia dotyczące bezpieczeństwa: WARNING! TO AVOID DANGER OF SUFFOCATION,KEEP AWAY FROM BABIES ANDCHILDREN. DO NOT USE IN CRIBS/BEDSOR PLAY PENS.THIS BAG IS NOT ATOY.
Składniki: Octinoxate 5.2867%
Numer części producenta: JK203027
Numer modelu: JK199930
Numer seryjny: JK062427
Numer partii: JK197038

Dostawa i zwroty

Wysyłka w ciągu 3 dni

  • EXPRESS: 48,49 zł - Dostawa między pon. 06 października 2025–śr. 15 października 2025

Wysyłka z Chiny

Dokładamy wszelkich starań, aby zamówione produkty były dostarczane w całości i zgodnie z Państwa wymaganiami. Jeśli jednak otrzymają Państwo niekompletne zamówienie, przedmioty inne niż zamówione lub istnieje inny powód, dla którego nie są Państwo zadowoleni z zamówienia, mogą Państwo zwrócić zamówienie lub dowolne produkty objęte zamówieniem i otrzymać pełny zwrot kosztów za te przedmioty. Pokaż pełną politykę zwrotów

Szczegóły zgodności produktu

Prosimy o zapoznanie się z informacjami dotyczącymi zgodności dotyczącymi tego produktu podanymi poniżej.

Poniższe informacje zostały dostarczone przez niezależnego sprzedawcę zewnętrznego sprzedającego ten produkt.

Producent:
Poniższe informacje zawierają dane kontaktowe producenta danego produktu sprzedawanego w serwisie Fruugo.

  • UMCU
  • shenzhenshixiangpulitiankejiyouxiangongsi
  • 301 (308), No. 32, Xiangyin Road, Nanlian Community, Longgang Street, Longgang District
  • Shenzhen
  • China
  • 518000
  • teuneva@126.com
  • 13535306199
  • https://www.fruugo.co.uk/umcu/m-17124?language=en

Osoba odpowiedzialna w UE:
Poniższe informacje zawierają dane kontaktowe osoby odpowiedzialnej w UE. Osobą odpowiedzialną jest wyznaczony przedsiębiorca z siedzibą w UE, który jest odpowiedzialny za wypełnianie obowiązków związanych z przestrzeganiem przepisów w odniesieniu do danego produktu sprzedawanego na terenie Unii Europejskiej.

  • EC REP SERVICES SL
  • EC REP SERVICES SL
  • Calle Gran Via 49, 7 DCH.
  • Madrid
  • Spain
  • 28013
  • ecrepservice@hotmail.com
  • 34682797075