Current Detection Sensor Module Digital Display 4‑20mA Relay Module Component DC12V

84,00 zł
DARMOWA wysyłka

Current Detection Sensor Module Digital Display 4‑20mA Relay Module Component DC12V

  • Marka: Unbranded
Sprzedawca:

Current Detection Sensor Module Digital Display 4‑20mA Relay Module Component DC12V

  • Marka: Unbranded

84,00 zł

Oszczędzasz 105,00 zł (55%)

Sugerowana cena detaliczna

189,00 zł
W magazynie
DARMOWA wysyłka
Sprzedawca:

84,00 zł

Oszczędzasz 105,00 zł (55%)

Sugerowana cena detaliczna

189,00 zł
W magazynie
DARMOWA wysyłka

Akceptujemy następujące metody płatności

Opis

1、Composed of professional PCB materials, stable performance and long service life. 2、Increase the power supply anti‑reverse protection to reduce the risks of work errors and improve work efficiency. 3、With three‑digit display, three‑button adjustment is convenient and easy to use. 4、The module with small size, easy to carry and store, convenient to use and with good performance. 5、Great workmanship, with strict quality control and quality assurance, high safety factor, can be used with peace of mind. Item Type: Current Detection Sensor Module Material: PCB Working Current: Standby: 12mA, Working: 56mA Working Voltage: DC12V Digital Display Life: ≥50,000 hours Relay Life: ≤100,000 times Digital Tube: 3 in 1 Working Temperature: -20℃~75℃ Measuring Range: 0-25mA Detection Signal: 4-20ma Product Features: 4-20ma Current Detection: After the module is powered on, the PX is initially displayed and the currently set mode is displayed. At this time, the mode can be adjusted by pressing the "+" and "-" buttons. It will enter the real-time display of the measured current after 4s. Three buttons to set the upper and lower limits and function mode selection Interface Description: Input Positive Pole: Connect to the positive pole of the power supply Negative Pole: Connect to the negative pole of the power supply AO: 4-20ma signal input COM: It is connected to the negative pole of the power supply Output NO: NO end COM: Public NC: NC end Several Modes Can be Set as Follows: (Long press "-" for 3s to enter the adjustment mode) P-1: Suction exceeds the set value, but is disconnected below the set value; the measured value exceeds the lower limit value and the relay suctions, and disconnects below the lower limit value. P-2: Disconnect when the value exceeds the set value, but is lower than the suction; when the measured value exceeds the lower limit, the relay is disconnected, and the suction is lower than the lower limit. P-3: Suction in the interval and disconnected outside the interval; the measured value is between the upper limit and the lower limit and the relay sucks, otherwise it is disconnected P-4: Disconnected in the interval, sucked outside the interval; the relay is disconnected between the upper limit and lower limit of the measured value, otherwise sucked P-5: Disconnect below the lower limit, and absorb above the upper limit; when the measured value exceeds the lower limit, the relay will disconnect, and the relay will absorb above the upper limit. P-6: Suction is lower than the lower limit, and it is disconnected above the upper limit; the measured value exceeds the lower limit and the relay is suctioned, and the relay is disconnected above the upper limit. Setting Instructions (for The Convenience Of Description, Use K1 For The setting key, K2 for the + key, and K3 for the-key): Key Description: "K1 shift/adjust; K2+; K3-/mode selection Press the K1 key, the first digit flashes, adjust the lower limit of hundreds, press K2, K3 to adjust 0~1 change Press the K1 button, the second digit will flash, adjust the tens digit of the lower limit, press K2, K3 to adjust 0-9 changes Press K1 key, the third lower third digit flashes, adjust the lower limit one digit, press K2, K3 to adjust 0-9 change Press the K1 key, the 4th, lower, and fourth digits will flash, adjust the upper limit of hundreds, press K2, K3 to adjust 0~1 changes Press K1 key, the 5th bottom fifth digit flashes, adjust the upper limit ten digits, press K2, K3 to adjust 0-9 changes Press K1 key, the 6th, lower and sixth digits will flash, adjust the upper limit one digit, press K2, K3 to adjust 0-9 changes Press the K1 key for the 7th time, the digital tube is not flashing, it displays the measured current value 1 x Current Detection Sensor Module
  • Identyfikator Fruugo: 363941782-789534867
  • EAN: 605788636603

Informacje o bezpieczeństwie produktu

Prosimy o zapoznanie się z informacjami dotyczącymi bezpieczeństwa produktu określonymi poniżej

Poniższe informacje zostały dostarczone przez niezależnego sprzedawcę zewnętrznego sprzedającego ten produkt.

Etykiety bezpieczeństwa produktu

CE Mark
Ostrzeżenia dotyczące bezpieczeństwa:
  • Not suitable for children under 36 months
  • Choking Hazard
  • Adult supervision recommended

Dostawa i zwroty

Wysyłka w ciągu 2 dni

  • STANDARD: BEZ OPŁAT - Dostawa między śr. 29 października 2025–czw. 06 listopada 2025 - BEZ OPŁAT

Wysyłka z Chiny

Dokładamy wszelkich starań, aby zamówione produkty były dostarczane w całości i zgodnie z Państwa wymaganiami. Jeśli jednak otrzymają Państwo niekompletne zamówienie, przedmioty inne niż zamówione lub istnieje inny powód, dla którego nie są Państwo zadowoleni z zamówienia, mogą Państwo zwrócić zamówienie lub dowolne produkty objęte zamówieniem i otrzymać pełny zwrot kosztów za te przedmioty. Pokaż pełną politykę zwrotów

Szczegóły zgodności produktu

Prosimy o zapoznanie się z informacjami dotyczącymi zgodności dotyczącymi tego produktu podanymi poniżej.

Poniższe informacje zostały dostarczone przez niezależnego sprzedawcę zewnętrznego sprzedającego ten produkt.

Producent:
Poniższe informacje zawierają dane kontaktowe producenta danego produktu sprzedawanego w serwisie Fruugo.

  • Jinan Haoteseer Cross Border E-commerce Co.. Ltd.
  • Jinan Haoteseer Cross Border E-commerce Co.. Ltd.
  • Shou Nuo Cheng Shi Zhi Guang Dong Zuo 9-43
  • Huaiyin District, Jinan
  • China
  • Jinan
  • CN
  • 250000
  • jnamei04@126.com
  • 13380966881

Osoba odpowiedzialna w UE:
Poniższe informacje zawierają dane kontaktowe osoby odpowiedzialnej w UE. Osobą odpowiedzialną jest wyznaczony przedsiębiorca z siedzibą w UE, który jest odpowiedzialny za wypełnianie obowiązków związanych z przestrzeganiem przepisów w odniesieniu do danego produktu sprzedawanego na terenie Unii Europejskiej.

  • WongBo
  • NG HOT SARL
  • 99 bis avenue du Général Leclerc
  • 99 bis avenue du Général Leclerc
  • France
  • Paris
  • FR
  • 75014
  • ngnghot@outlook.com
  • 33695000695
  • https://www.captaincontrat.com/creer-son-entreprise/sarl/capital-social-de-sarl-montant-minimum-constitution-modification...tout-savoir