Power Monitoring Communication Module TTL for AC Voltage Current Power Frequency with CT(100A COil CT )

99,00 zł
DARMOWA wysyłka

Power Monitoring Communication Module TTL for AC Voltage Current Power Frequency with CT(100A COil CT )

  • Marka: Unbranded
Sprzedawca:

Power Monitoring Communication Module TTL for AC Voltage Current Power Frequency with CT(100A COil CT )

  • Marka: Unbranded

99,00 zł

Oszczędzasz 30,00 zł (23%)

Sugerowana cena detaliczna

129,00 zł
W magazynie
DARMOWA wysyłka
Sprzedawca:

99,00 zł

Oszczędzasz 30,00 zł (23%)

Sugerowana cena detaliczna

129,00 zł
W magazynie
DARMOWA wysyłka

Akceptujemy następujące metody płatności

Opis

Feature:1. This AC parameter communication module is mainly used to measure AC voltage, current, active power, frequency, power factor and active energy.2. The module has no display function and the data is read through the TTL interface.3. Support for Modbus-RTU standard protocol, including host computer software.4. Comes with TTL to USB data cable and external CT.5. The module works for Windows operating systems.Specification:Item Type: Communication ModuleMeasurement Range: AC 80-260VResolution: 0.1 VAccuracy:0.5%2. Current:Measurement Range:0-100AResolution: 0.001 AAccuracy: 0.5%3. Active PowerMeasurement Range:0-2.3 KWMin. Measuring Power: 0.4WResolution: 0.1W4. Power FactorMeasurement Range: 0.00-1.00Resolution: 0.01Accuracy:1%5. FrequencyRange:45 Hz-65 HzResolution: 0.1 HzAccuracy: 0.5%6. Active Electrical EnergyMetering Range:0-9999.99 kWhResolution: 1WhAccuracy: 0.5%Communication Protocol:1. Physical layer protocol:Physical layer adopts UART to TTL communication interfaceBaud rate:9600,8 bit data bit,1 bit stop bit, no check2. Application layer protocolThe application layer supports for Modbus-RTU protocol for communication and currently only supports function codes such as 0x03 (read-hold register), 0x04 (read-input register), 0x06 (write single register), 0x41 (calibration), 0x42 (power zero).The 0x41 function code is limited to internal use (the address can only be 0xF8), used for factory calibration and back-to-factory maintenance, add a password of 16 bits after the function code, the password default is 0x3721.The address range of the slave computer is 0x01 ~ 0xF7, and the address 0x00 is used as the broadcast address. The slave computer does not need to reply to the host, and the address 0xF8 is used as the general address. The address can only be used in a single-slave environment and can be used for calibration and other operations.3. Read the results of the measurementThe command format for the host to read the result of the measurement is (8 bytes in total):Slave computer address + 0x04 + register address high byte + register address low byte + register number high byte + register number low byte + CRC check high byte + CRC check low byte.Reply of slave computer to the following command format is divided into two types:Correct reply: Slave computer address + 0x04 + bytes + registers 1 data high byte + registers 1 data low byte +...+ CRC check high byte + CRC check low byte.Wrong reply: Slave computer address + 0x84 + exception code + CRC check high byte + CRC check low byte.The exception code is read as follows (the same below):0x01, illegal function; 0x02, illegal address; 0x03, illegal data; 0x04, slave error.The register layout of the measured results is shown in the following table:v\:* {behavior:url(#default#VML);}o\:* {behavior:url(#default#VML);}x\:* {behavior:url(#default#VML);}.shape {behavior:url(#default#VML);}Register addressDescriptionResolution0x000Voltage value measurement1LSB corresponds to 0.1V0x001Current Measurement Value Low 16 Bits1LSB corresponds to 0.01A0x0002Current Measurement Value High 16 Bits0x0003Power Measurement Value Low 16 Bits1LSB corresponds to 0.1W0x0004Power Measurement Value High 16 Bits0x0005Energy Measurement Value Low 16 Bits1LSB corresponds to 1Wh0x0006Energy Measurement Value High 16 Bits0x0007Frequency Measurement Value1LSB corresponds to 0.1Hz0x0008Power Factor Measurement Value1LSB corresponds to 0.010x0009Alarm State0xFFFF alarm0x0000 no alarm4. Read and modify the slave parametersIt supports reading and modifying the address and power alarm settings of the slave machine5. Zero power6. Calibration7. CRC checkPackage List:1 x Module1 x Data Cable1 x CT1 x User ManualNote:The module TTL interface is a passive interface, it needs external 5V power supply, all 4 ports must be linked at the time of communication, otherwise it can't communicate.
  • Identyfikator Fruugo: 425661443-894088036
  • EAN: 7599075566151

Dostawa i zwroty

Wysyłka w ciągu 2 dni

  • STANDARD: BEZ OPŁAT - Dostawa między pt. 31 października 2025–czw. 06 listopada 2025 - BEZ OPŁAT

Wysyłka z Chiny

Dokładamy wszelkich starań, aby zamówione produkty były dostarczane w całości i zgodnie z Państwa wymaganiami. Jeśli jednak otrzymają Państwo niekompletne zamówienie, przedmioty inne niż zamówione lub istnieje inny powód, dla którego nie są Państwo zadowoleni z zamówienia, mogą Państwo zwrócić zamówienie lub dowolne produkty objęte zamówieniem i otrzymać pełny zwrot kosztów za te przedmioty. Pokaż pełną politykę zwrotów

Szczegóły zgodności produktu

Prosimy o zapoznanie się z informacjami dotyczącymi zgodności dotyczącymi tego produktu podanymi poniżej.

Poniższe informacje zostały dostarczone przez niezależnego sprzedawcę zewnętrznego sprzedającego ten produkt.

Producent:
Poniższe informacje zawierają dane kontaktowe producenta danego produktu sprzedawanego w serwisie Fruugo.

  • Shenzhen Mutalai Technology Co., Ltd.
  • Shenzhen Mutalai Technology Co., Ltd.
  • 71001-187, 7/F, Building D, Gaoke Mansion, No. 2076 Yuanyuan Avenue
  • Nanshan Street
  • Nanshan District
  • Shenzhen
  • CN
  • 518000
  • gbyhynnygt@126.com
  • 18664978705
  • https://detail.1688.com/offer/593788918206.html?spm=a2615.7691456.autotrace-offerGeneral.7.4cc915345wLsDx

Osoba odpowiedzialna w UE:
Poniższe informacje zawierają dane kontaktowe osoby odpowiedzialnej w UE. Osobą odpowiedzialną jest wyznaczony przedsiębiorca z siedzibą w UE, który jest odpowiedzialny za wypełnianie obowiązków związanych z przestrzeganiem przepisów w odniesieniu do danego produktu sprzedawanego na terenie Unii Europejskiej.

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795
  • https://www.noon.com/uae-en/p-29378/