DIN Rail Led Single Phase LCD-Digital Display Voltmeter Ammeter Consumption Energy Panel Voltage Current Meter Wattmeter

189,00 zł
DARMOWA wysyłka

DIN Rail Led Single Phase LCD-Digital Display Voltmeter Ammeter Consumption Energy Panel Voltage Current Meter Wattmeter

  • Marka: Unbranded
Sprzedawca:

DIN Rail Led Single Phase LCD-Digital Display Voltmeter Ammeter Consumption Energy Panel Voltage Current Meter Wattmeter

  • Marka: Unbranded

189,00 zł

W magazynie
DARMOWA wysyłka
Sprzedawca:

189,00 zł

W magazynie
DARMOWA wysyłka

Akceptujemy następujące metody płatności

Opis

Features: Measurement accuracy: 1%±2 wordsMeasuring ranges: ACvoltage: AC40.0-300.0V, (orAC250.0-450.0V), users can choose a suitable measuring ranges when ordering) Accurrent: AC0-100.0A, and current display resolution is 0.01APower frequency: 45.0Hz-65.0HzPower factor: 0.00-1.00PF Active power: the measuring ranges is 0-45000W, the display resolution between 0-9999.9Wis 0.1W, and the rest is1W Electric energy: the measuring ranges is0-99999kwh, and the minimum display resolution of 0-999.99kwh is 0.01kwh.The minimum display resolution of 1000.0-9999.9kwh is 0.1kwh.The minimum resolution of 10000-99999kwh is 1kwh Measuring speed: about 2 times per secondOverall dimensions: 54x80x64mm/2.12x3.14x2.51inchInstallation method: guide rail type Specifications: Material:Plastic Size: Approx.5.4x8x6.4cm/2.12x3.14x2.51inch Measuring range: AC-voltage: AC40.0-300.0V, (or AC250-450V). Ac-current: AC0-100.0A, and current display resolution is 0.01A Power frequency: 45.0Hz-65.0Hz Power factor: 0.00-1.00PF The minimum display resolution of 1000-9999.9kwh is 0.1kwh. The minimum resolution of 10000-99999kwh is 1kwh. Measuring speed: about 2-times per second Package Includes: 1x Current Power Meter note: Usage and wiring methods 1. Connect the measured voltage to terminals 1 and 2 at the lower left of the instrument. 2. The built-in transformeris wiredaccording to the wiring diagramin Figure 1, and the lead of the measuring circuit passesthrough the round hole belowthe instrument. The user can choose the direction of the lead according to the use situation, and it can pass through the round hole belowthe instrument or pass through the round hole above the instrument, and the measurement result will not be affected if the direction is different. 3. Connect the external transformeraccording to the wiring diagramin Figure 2. Connectthe two wires of the secondary end of the precisions current transformerwith the instrument to the terminals 3 and 4 at the upper left of the instrument respectively, and pass thewires of the measuring circuit through thecircular hole of thetransformer. 4. The measured parameters displayed by the instrument after the power supply isconnected. 5. When it is necessary to reset the electric energy measurement (when measuring fromzeros), press and hold the button (reset) on the right side of the instrument panel for 5 seconds (hold and hold for 5 seconds) until the electric energy shows 0, release the button, and then the electric energy will be measured fromzeros. Electric energy has the function of automatically saving data in case of power failure, that is, when the measuring voltage is disconnected or power failure, the instrument will automatically savethe data currentlytested, and when the measuring power supply is reconnected, the instrument will continue to accumulate on the originalsaved data.
  • Identyfikator Fruugo: 368889798-799074770
  • EAN: 7923024648832

Dostawa i zwroty

Wysyłka w ciągu 24 godzin

  • STANDARD: BEZ OPŁAT - Dostawa między pt. 31 października 2025–śr. 05 listopada 2025 - BEZ OPŁAT

Wysyłka z Chiny

Dokładamy wszelkich starań, aby zamówione produkty były dostarczane w całości i zgodnie z Państwa wymaganiami. Jeśli jednak otrzymają Państwo niekompletne zamówienie, przedmioty inne niż zamówione lub istnieje inny powód, dla którego nie są Państwo zadowoleni z zamówienia, mogą Państwo zwrócić zamówienie lub dowolne produkty objęte zamówieniem i otrzymać pełny zwrot kosztów za te przedmioty. Pokaż pełną politykę zwrotów

Szczegóły zgodności produktu

Prosimy o zapoznanie się z informacjami dotyczącymi zgodności dotyczącymi tego produktu podanymi poniżej.

Poniższe informacje zostały dostarczone przez niezależnego sprzedawcę zewnętrznego sprzedającego ten produkt.

Producent:
Poniższe informacje zawierają dane kontaktowe producenta danego produktu sprzedawanego w serwisie Fruugo.

  • Shenzhen Jianming Technology Co., Ltd.
  • Shenzhen Jianming Technology Co., Ltd.
  • 611, 6th Floor, Longsheng Commercial Building, Dalang Street
  • Shenzhen
  • China
  • 518000
  • asued2wmeqc@163.com
  • 18818900735

Osoba odpowiedzialna w UE:
Poniższe informacje zawierają dane kontaktowe osoby odpowiedzialnej w UE. Osobą odpowiedzialną jest wyznaczony przedsiębiorca z siedzibą w UE, który jest odpowiedzialny za wypełnianie obowiązków związanych z przestrzeganiem przepisów w odniesieniu do danego produktu sprzedawanego na terenie Unii Europejskiej.

  • Yating He
  • E-CrossStu GmbH
  • 69 Mainzer Landstrasse
  • Frankfurt am Main
  • Germany
  • 60329
  • E-crossstu@web.de
  • +4969332967674